pump discharge pressure for smooth bore nozzle

Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone. (* is required).

  • Pump Discharge Pressure - loresoft.com

    2020-9-14 · Pump Discharge Presure. PDP = NP + FL + AFL +/- EL. Nozzle Pressure (NP) Fog Nozzle 100 psi Smooth Bore Handline 50 psi Smooth Bore Master 80 psi Single Hose Friction Loss (FL) Hose: GPM: Length: Smooth Bore Nozzle ...

    Get Price
  • Developing Accurate Pump Discharge Pressures | Fire ...

    2018-7-1 · Table 2. Flow Comparison for Stacked Tips Pumped at the Highest PDP: Tip. Nozzle Pressure. Gallons per Minute. 2-inch. 110. 1,060. 1¾-inch . 80. 814 . 1½-inch. 90

    Get Price
  • RULE OF EIGHT’S FOR SMOOTH BORE MASTER STREAMS

    2019-4-16 · Pump Discharge or Engine Pressure = Nozzle Pressure + Friction Loss + Device ± Elevation NR = 1.57 x D² x NP (Smooth Bore Nozzle) Nozzle Reaction = 1.57 x (Diameter of Nozzle Tip)² x Nozzle Pressure NR = 0.0505 x Q x √NP (Fog Nozzle) GPM = 29.7 x D² x √NP (Smooth Bore Nozzle) Gallons per minute = 29.7 x (diameter)² x √ nozzle pressure

    Get Price
  • What is a smooth bore nozzle? - FindAnyAnswer.com

    2020-4-14 · Then, what do you pump a smooth bore nozzle at? The operating pressure of the smooth bore is a range from 40 to 60 pounds per square inch (psi), with 50 psi as optimal.. Beside above, what is considered a master stream? A master stream is basically defined as a heavy-caliber stream delivered through a master stream water delivery appliance. A master stream is used …

    Get Price
  • Calculating pump-discharge-pressure-made-easy

    2017-9-7 · Nozzle Pressure (PSI) 16 16 16 16 16 17 17 ... SMOOTH BORE DISCHARGE DATA POCKET FLOW GUIDE (GPM) 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 105 110 115 120 125 130 135 140 145 150 175 200 P.O. Box 1127, Elkhart, IN 46515 • 1.574.295.8330 • 1.800.346.0250 • www.elkhartbrass.com • Email: [email protected]fleet.net

    Get Price
  • SMOOTH BORE POCKET FLOW GUIDE - Elkhart Brass

    2020-12-11 · smooth bore nozzle any larger than 1¼ inches. A 1¾-inch hand-line should have a nozzle tip no larger than 7⁄8 inch. the amount of water discharging from a smooth bore is determined by the nozzle pressure and the inside diameter of the opening. the formula for determining the gpm flow from a smooth bore nozzle is as follows:

    Get Price
  • Every Pump Operator’s Basic Equation

    2016-4-13 · For any size SMOOTH BORE nozzle, the discharge for fresh water can be approximately determined by this formula. GPM = 30 d2 NP Where d = diameter of smooth bore tip, and NP = Nozzle Pressure There are only two square root numbers to choose from for these calculations. 7 HINT Hand held smooth bore - 50 psi = Deck gun, Deluge or Monitor - 80 psi = 9

    Get Price
  • FIREGROUND HYDRAULICS

    Compare the flow and reach of each nozzle from Akron Brass using both our smooth bore nozzle flow charts and other nozzle gpm charts. Cookie Policy This site uses and sets 'cookies' on your computer to help make this website better.

    Get Price
  • Smooth Bore Nozzle Flow Chart - Akron Brass

    2020-2-29 · Reducing the nozzle pressure is an option and is being applied as U.S. fire departments are switching from high-pressure fog nozzles (100 psi) to smooth bore nozzles or low-pressure fog nozzle (50 ...

    Get Price
  • What pressure do you pump a master stream?

    Having a good understanding of pump discharge pressure is essential to becoming an effective fire engine operator. In this regard, what do you pump a smooth bore nozzle at? A smoothbore handline's optimum tip pressure is 50 PSI. This means at 50 PSI, your tip size of choice should give you good reach, penetration, a desired nozzle reaction, and ...

    Get Price
  • FIREGROUND HYDRAULICS

    2016-4-13 · For any size SMOOTH BORE nozzle, the discharge for fresh water can be approximately determined by this formula. GPM = 30 d2 NP Where d = diameter of smooth bore tip, and NP = Nozzle Pressure There are only two square root numbers to choose from for these calculations. 7 HINT Hand held smooth bore - 50 psi = Deck gun, Deluge or Monitor - 80 psi = 9

    Get Price
  • PRODUCT LINEUP - Elkhart

    2019-1-14 · • Smooth Bore Discharges & Flow/Pressure • Nozzle Reaction for Smooth Bore Nozzles • Nozzle Reaction for Fog Nozzles • Pump Discharge Pressure for standard layouts, with ability to input hose coefficient depending on make and inside diameter • Pump Discharge Pressure with elevation changes and appliances

    Get Price
  • Smooth Bore Show Down - TFT

    2018-5-23 · automatic, 7/8” smooth bore. Dual-Force (50 to 250 gpm) is the hydraulic equal of a one inch tip. 7/8” smooth bore at 50 psi flows about 165 gpm 1” smooth bore at 50 psi flows about 200 gpm. 1997 pressure in the center! flow control at the nozzle, not the pump www.cottrellinc.com Smooth Bore Show Down & MidMatic-MidForce Evaluation Need help?

    Get Price
  • Theoretical Discharge And Reaction - Akron Brass

    Theoretical Discharge and Reaction. Solid Bore Nozzles (PDF) - View the nozzle pressure, gallons per minute (GPM), reaction force in pounds and bore dimensions for solid bore nozzles. Fog Nozzles (PDF) - View the GPM settings, gallons per minute (GPM), reaction force in pounds and nozzle pressure at inlet for fog nozzles.

    Get Price
  • Calculating pump-discharge-pressure-made-easy

    2015-5-26 · GPM is generally determined by Nozzle Tip Size. Once the GPM is determined, then Friction Loss can be calculated for that GPM and the size of the fire hose that will be used. Device pressures must also be added to the Pump Discharge Pressure for each line. 1) The Officer should determine the fire load and how many Gallons Per Minute of water ...

    Get Price
  • Friction Loss Formula for Fire Hydaulics - Cheat Sheet ...

    Nozzle Pressures Smooth Bore o Hand-held = 50psi o Master = 80psi Fogs (including fogs on master stream devices) o Most fogs = 100psi NOZZLE REACTION Newton’s Third Law of Motion, “For every action there is an equal and opposite reaction.” ... As pump discharge pressure varies in response to changing discharge volumes, the reference ...

    Get Price
  • Nozzle Knowledge Is More Than Just Smooth Bore or Fog ...

    2020-2-29 · Reducing the nozzle pressure is an option and is being applied as U.S. fire departments are switching from high-pressure fog nozzles (100 psi) to smooth bore nozzles or low-pressure fog nozzle (50 ...

    Get Price
  • FST 205 Flashcards | Quizlet

    In comparing the flow between a smooth-bore nozzle and a fog nozzle of equal size: the fog nozzle flows less water. ... As the pump discharge pressure is increased, the capacity of the pump: must go down. (pg 126) During pump testing, the water supply should be at least 35°F, but not over _____°F, and the air temperature should be between 0 ...

    Get Price
  • Chapter 16 Flashcards | Quizlet

    If the nozzle is above the fire pump, nozzle pressure is decreased. To extinguish by cooling, the fire stream must: ... When used with a smooth bore nozzle, a nozzle control valve that causes turbulence when partially open which can affect the quality of a fire stream is the: ... Increasing discharge pressure and flow rate increases nozzle ...

    Get Price
  • Pump Chart - cdpsdocs.state.co.us

    2020-1-8 · PP Pump Pressure 2 ½” hose 2 TPDP Total Pump Discharge Pressure 2 ½” Siamese line .5 3” w/2 ½” couplings 0.8 3” w 3” couplings 0.677 4” hose 0.2 5” hose 0.08 4” Standpipe 0.374 5” Standpipe 0.126 6” Standpipe 0.052 Calculating GPM for Smooth Bore nozzles: Formula: GPM=29.7 x d² x √NP

    Get Price
  • Pennwell Supplements - FE July 2018 Water on the Fire ...

    Determining Pump Discharge Pressure. ... Use both when testing a smooth-bore nozzle; rely on the flowmeter only when working with combination nozzles and specialty nozzles such as the vindicator and piercing nozzles. Fixed Master Stream. A fixed master stream is preconnected to the top of the engine by plumbing. To determine the PDP for this ...

    Get Price
  • Smooth Bore Data - Elkhart Brass

    2015-3-23 · SMOOTH-BORE NOZZLES Smooth bore nozzles generate effective streams at nozzle pressures as low 30 PSI, but the stream will degrade at pressures over 60 PSI. FLOW RATE & REACTION FORCE 7/8' TIP NOZZLE PRESS. 15/16' TIP 1' TIP 1 1/16' TIP 1 1/8' TIP 1 3/16' TIP. ELKHARIVBRASS Fire Fighting Equipment . Title: Smooth Bore Data.xlsx Author:

    Get Price
  • Download the Elkhart Hard Facts Calculator App Today ...

    Nozzle Reaction for Smooth Bore Nozzles Nozzle Reaction for Fog Nozzles Pump Discharge Pressure for standard layouts, with ability to input hose …

    Get Price
  • 5 things firefighters must know about nozzles

    2020-9-12 · The basic formula for calculating pump discharge pressure is PDP = NP + TPL — PDP is the pump discharge pressure, NP is the nozzle pressure and TPL is the total pressure …

    Get Price
  • How to calculate GPM (water flow) for a fire pump? What ...

    2016-4-20 · A1¾-inch handline should have a nozzle tip no larger than7⁄8 inch.The amount of water discharging from a smooth bore is determined by the nozzle pressure and the inside diameter of the opening. The formula for determining the GPM flow from a smooth bore nozzle is as follows:.D2√P (D = nozzle diameter; √P = square root of pressure)

    Get Price
  • How to Calculate Nozzle Reaction - US Forest Service

    2013-3-30 · Calculating the Nozzle Reaction for a 1.25-inch-Bore-Diameter Nozzle The solid bore discharge formula is gallons per minute (gpm) = 29.71 D² NP¹/². The formula can be rewritten to solve for the unknown, nozzle pressure: Nozzle Pressure = NP psi = [(gpm)/(29.71 x D²)]² Where: gpm = 400 gpm. bore diameter (D) = 1.25 in. therefore:

    Get Price
  • Vincicator Nozzles - Frequently asked Questions

    2010-9-12 · Flow rates for smooth bore nozzles are obviously determined by the size of the bore and the pressure. The most commonly used tip sizes for a 1¾' hose are the 7/8' and 15/16', which flow 161 gpm and 185 gpm respectively at 50 psi NP. Common smooth bores for a 2½' hose line are the 1' or 1¼', which flow 211 gpm and 330 respectively at 50 psi NP.

    Get Price
  • Two-Inch Hose: the Lightweight Preconnected Little Big ...

    2014-6-9 · The nozzles used for this test are smooth bore tips for a 50-psi nozzle pressure. Because the two-inch will have a higher friction loss at the high flows we tried to achieve, a nozzle with a low nozzle pressure kept the overall discharge pressure as low as possible.

    Get Price
  • Nozzle Types, Pros and Cons | FirefighterNation

    2012-6-21 · When using any nozzle to extinguish a fire, keep in mind that actual flow may be affected by many variables, such as differences in piping from the pump to the discharge point, increasing friction ...

    Get Price
  • Smooth Bore Data - Elkhart Brass

    2015-3-23 · SMOOTH-BORE NOZZLES Smooth bore nozzles generate effective streams at nozzle pressures as low 30 PSI, but the stream will degrade at pressures over 60 PSI. FLOW RATE & REACTION FORCE 7/8' TIP NOZZLE PRESS. 15/16' TIP 1' TIP 1 1/16' TIP 1 1/8' TIP 1 3/16' TIP. ELKHARIVBRASS Fire Fighting Equipment . Title: Smooth Bore Data.xlsx Author:

    Get Price
  • Pump Chart - cdpsdocs.state.co.us

    2020-1-8 · PP Pump Pressure 2 ½” hose 2 TPDP Total Pump Discharge Pressure 2 ½” Siamese line .5 3” w/2 ½” couplings 0.8 3” w 3” couplings 0.677 4” hose 0.2 5” hose 0.08 4” Standpipe 0.374 5” Standpipe 0.126 6” Standpipe 0.052 Calculating GPM for Smooth Bore nozzles: Formula: GPM=29.7 x d² x √NP

    Get Price
  • Vincicator Nozzles - Frequently asked Questions

    2010-9-12 · Flow rates for smooth bore nozzles are obviously determined by the size of the bore and the pressure. The most commonly used tip sizes for a 1¾' hose are the 7/8' and 15/16', which flow 161 gpm and 185 gpm respectively at 50 psi NP. Common smooth bores for a 2½' hose line are the 1' or 1¼', which flow 211 gpm and 330 respectively at 50 psi NP.

    Get Price
  • Friction Loss Formula for Fire Hydaulics - Cheat Sheet ...

    Nozzle Pressures Smooth Bore o Hand-held = 50psi o Master = 80psi Fogs (including fogs on master stream devices) o Most fogs = 100psi NOZZLE REACTION Newton’s Third Law of Motion, “For every action there is an equal and opposite reaction.” ... As pump discharge pressure varies in response to changing discharge volumes, the reference ...

    Get Price
  • Smooth bore Nozzles - Firehouse Forums - Firefighting ...

    2001-4-28 · To keep everyone happy, we purchased some combination nozzles with the screw off fog head that turns the nozzle into a 15/16-inch smooth bore. Everyone pretty much seems to be comfortable with them. Actually the hardest part was tying to get our chauffeurs familiar with pumping at a lower pressure and making sure the hose being used has the ...

    Get Price
  • Put the Pump Chart on the Pump Panel - FireRescue1

    2009-8-20 · For instance, a 15/16' smoothbore nozzle at 50-psi nozzle pressure is designed to produce 185-gpm. If this is the nozzle carried on a preconnected line, …

    Get Price
  • MANUAL: VALVE INTEGRAL TIP (VIT) NOZZLE

    2019-4-17 · The VIT nozzle has fixed orifice sizes. Relationship of flow and nozzle pressure at each orifice size is shown below. If the VIT nozzle is connected behind a different nozzle, use the flow charts for the outlet nozzle. Contact the factory or visit the website (www. tft.com) for range and trajectory data. 0.000 1.000 2.000 3.000 4.000 5.000 6 ...

    Get Price
  • Send The Water : Supplying Aerial Master Streams-An

    2013-2-3 · Using a smooth bore tip on an aerial monitor will lower your supply pump pressure 20 PSI compared to using a 100 PSI automatic nozzle, because the smooth bore only requires 80 PSI at the tip for its 'rated flow'.

    Get Price
  • 1 1/2' Hose Nozzles

    1 1/2' smooth bore red polycarbonate nozzle. NPSH and NPT are more common in industrial applications. How we conducted our nozzle testing. We used a Honda self-priming water pump with a two inch inlet and a two inch outlet that produces 135 gallons per minute (GPM). The nozzle was attached to a fifty foot 1 1/2 inch fire hose.

    Get Price
  • High Rise Fire-fighting : Branches (Nozzles)

    2017-2-15 · A well balanced attack may consist of 2 hose lines, one terminating in a smooth bore branch (19-22mm) and a suitable low pressure/high flow combination branch. With this combination, modern compartment fire-fighting techniques and, perhaps “old fashion” high flow solid jets, can be used together or in isolation to provide the best attack of ...

    Get Price
  • Pump Operation Review - Montgomery County, Maryland

    2015-3-25 · Pump Discharge or Engine Pressure = Nozzle Pressure + Friction Loss + Device ± Elevation NR = 1.57 x D² x NP (Smooth Bore Nozzle) Nozzle Reaction = 1.57 x (Diameter of Nozzle Tip)² x Nozzle Pressure NR = 0.0505 x Q x √NP (Fog Nozzle) GPM = 29.7 x D² x √NP (Smooth Bore Nozzle) Gallons per minute = 29.7 x (diameter)² x √ nozzle ...

    Get Price
  • 1 OAK Engineer - Pump Chart Flashcards

    Pump discharge pressure for 200' of 1 3/4' hose and a nozzle? Definition. 110 psi: Term. Pump discharge pressure for 300' of 1 3/4' hose and a nozzle? Definition. 140 psi: ... Ground monitor equipped with a smooth bore tip's nozzle pressure? Definition. 80 psi: Term. F: Definition. Supporting users have an ad free experience! Tweet . My ...

    Get Price
  • Fire nozzle gpm chart – Security sistems

    Discharge table for smooth bore nozzles – Cascade Fire Equipment. One with 175-gpm at 75-psi fog nozzle and the other a 1516-inch. Discharge table for smooth bore nozzles – Cascade Fire Equipment NOZZLE. Fire department hydraulics charts used to calculate friction loss for pumping problems. Pump Chart 2012.pdf Fire Attack (very wet or wet ...

    Get Price
  • FRC | News » Archive » An Inside Look at Pump Testing

    2010-6-1 · As an example, we’ll assume the pump is a 1000 GPM 2 stage pump. According to the flow chart table listed in NFPA 1911, the smooth bore nozzle on the discharge monitor would have to be 2 inches in diameter. At a nozzle pressure of 72 PSI and a net pump pressure of 150 PSI you will be flowing water at a rate of 1008 GPM.

    Get Price
  • Solid Bore Nozzle Flow Chart - David's Fire

    2020-12-30 · Solid Bore Nozzle Flow Chart. The chart below lists the common solid bore nozzles used in testing fire pumps and their flow rating at set pressures. All nozzle pressures are pitot gauge readings, not pump pressure gauge readings. Flows are in U.S. gallons per minute. We have only shown the most popular tips sizes.

    Get Price
  • Calculating pump-discharge-pressure-made-easy

    Page 1 of 3 CALCULATING PUMP DISCHARGE PRESSURE – MADE EASY Compliments of [email protected] www.station31.org/calculating-pump-discharge-pressure.pdf - update…

    Get Price
  • Chapter 6 - Hose Nozzles and Flow Rates Flashcards by ...

    A _____ flow fog nozzle is designed to flow a specific volume of water on all stream patterns at a specific nozzle discharge pressure. Constant flow nozzle p 197 ... Smooth bore streams are generally operated at _____ psi nozzle pressure, while fog appliances are generally operated at _____ psi. ... Ch. 1 Types Of Apparatus Equipped With A Pump

    Get Price
  • Put the Pump Chart on the Pump Panel - FireRescue1

    2009-8-20 · For instance, a 15/16' smoothbore nozzle at 50-psi nozzle pressure is designed to produce 185-gpm. If this is the nozzle carried on a preconnected line, …

    Get Price
  • How to calculate GPM (water flow) for a fire pump? What

    The formula for determining the GPM flow from a smooth bore nozzle is as follows:.D2√P (D = nozzle diameter; √P = square root of pressure) For example, a one-inch smooth bore tip will have a discharge of gpm:. × ×7. = gpm.

    Get Price
  • Chapter 6: Hose Nozzles and Flow Rates Flashcards by

    Hose stream that stays together as a solid mass, as opposed to a fog or spray stream; a solid stream is produced by a smooth bore nozzle and should not be confused with a straight stream 3 Smooth bore hand line nozzles should be operated at ____ psi nozzle pressure, while smooth bore master stream appliances should be operated at a maximum of ...

    Get Price
  • Task Force Tips - FAQs

    The formula for a smooth bore nozzle is NR = 1.57 times d squared times NP. 1.57 is a constant d is the diameter in inches NP is Nozzle Pressure in psi. ... WHAT PUMP DISCHARGE PRESSURE SHOULD I OPERATE A RUBBER LINED 1 1/2' OF 150' AND 200' WITH A TFT 50-350GPM. WHAT IS MY GPM FLOW FOR BOTH (150'AND 200') SECTIONS OF RUBBER LINED 1 1/2' WITH A ...

    Get Price
  • 1 OAK Engineer - Pump Chart Flashcards

    Pump discharge pressure for 200' of 1 3/4' hose and a nozzle? Definition. 110 psi: Term. Pump discharge pressure for 300' of 1 3/4' hose and a nozzle? Definition. 140 psi: ... Ground monitor equipped with a smooth bore tip's nozzle pressure? Definition. 80 psi: Term. F: Definition. Supporting users have an ad free experience! Tweet . My ...

    Get Price
  • Pump Operation Review - Montgomery County, Maryland

    2015-3-25 · Pump Discharge or Engine Pressure = Nozzle Pressure + Friction Loss + Device ± Elevation NR = 1.57 x D² x NP (Smooth Bore Nozzle) Nozzle Reaction = 1.57 x (Diameter of Nozzle Tip)² x Nozzle Pressure NR = 0.0505 x Q x √NP (Fog Nozzle) GPM = 29.7 x D² x √NP (Smooth Bore Nozzle) Gallons per minute = 29.7 x (diameter)² x √ nozzle ...

    Get Price
  • Plunger Pumps Models 5DX30G1,5DX35G1 5DX40G1,5DX50G1

    2018-4-17 · flow through the pump without discharge restriction) to assure full system pressure is reached. Chemical draw occurs under low pressure. Select the Change over Nozzle(32149), Adjustable (32151), or Vari-Nozzle (7940-7980) to permit the adjustment from low to high pressure.

    Get Price
  • EXPLODED VIEW 67DX39G1I PLUNGER PUMP With Integral ...

    2018-4-17 · Pump should be purged of air before commencing with oper-ation. Liquid must flow through the pump without discharge restriction to assure full system pressure is reached. Install a pressure gauge close to the manifold head of the pump to assist in setting system pressure and to periodically monitor system pressure.

    Get Price
  • HSE: Q&Ans:Tell me about the pressure measurement of

    2020-2-29 · Fog nozzle, 100 psi nozzle pressure Adjustable gallonage nozzle Engine Pressure (EP): Engine pressure is the holy grail of pump operators. This is the number in psi that we need to see on our gages at the pump panel. Engine pressure is the sum of the nozzle pressure + the friction loss + any elevation or devices.

    Get Price
  • 2' Hose Nozzles

    NPSH and NPT are more common in industrial applications. How we conducted our nozzle testing. We used a Honda self-priming water pump with a two inch inlet and a two inch outlet that produces 135 gallons per minute (GPM). The nozzle was attached to a fifty foot 2 inch fire hose. The pump pressure was approximately 60 psi.

    Get Price
  • 200 GPM - Renton Fire & Emergency Services | slideum.com

    Restriction Designed Nozzle Pressure Smooth Bore Nozzle - Hand line - 50 PSI ½” thru 1 ¼” nozzles Smooth Bore Nozzle - Master Stream - 80 PSI nozzles 1 ¼” and over Fog Nozzle all nozzles - 100 PSI Solid Stream Characteristics The mechanical characteristics of a solid stream nozzle produce a compact stream that has a higher mass and ...

    Get Price
  • HSE: September 2015 - bloghse.com

    2020-2-29 · Fog nozzle, 100 psi nozzle pressure Adjustable gallonage nozzle Engine Pressure (EP): Engine pressure is the holy grail of pump operators. This is the number in psi that we need to see on our gages at the pump panel. Engine pressure is the sum of the nozzle pressure + the friction loss + any elevation or devices.

    Get Price
  • Driver Operator Manual Chapter 3 - Fireground Hydraulics

    2019-5-28 · 7 6th Principle: The pressure of a liquid on the bottom of a container is independent of the shape of the vessel. 5 Types of Pressure Static Pressure: Water at rest or not moving. Flow Pressure: The velocity of water coming from a discharge opening. Residual Pressure: Pressure remaining when water is flowing. Elevation Pressure: Pressure gain or loss due to elevation.

    Get Price