  • Chemical Pump Dosing Rates Spreadsheet - HydroFlo

    2013-11-5 · Last modified by: Tony Summers Created Date: 2/12/1997 2:32:42 PM Title: Chemical Pump Dosing Rates Spreadsheet Other titles: Acid Calc Caustic Calc Coag Calc Floc Calc 'Coag Calc'!Print_Area 'Floc Calc'!Print_Area

    Get Price
  • Chemical Pump Dosing Rates Spreadsheet -

    2021-5-11 · Below is a link to a spreadsheet developed by HydroFlo Tech. By inputting the major design criteria, you can solve for total chemical consumption as well as GPM & GPH dosing rates. The spreadsheet operates on Microsoft Excel 2003, or later. Chemical Pump Dosing Rates. Below is a sample shot of the spreadsheet.

    Get Price
  • Calculating Chemical Dose

    2019-4-8 · and calibration cylinder, measure the chemical feed pump rate (below). Then fill in the numbers and use a calculator to find the current values for each of the colored boxes. Finally, plug those values in to the equation at the bottom, and use a calculator to determine the current dose. DOH Publication 331-592 April 2017.

    Get Price
  • chemical dosing guidance - Avista Technologies

    2009-4-24 · Dosing Pump The dosing pumps should be sized to allow the specified dose at between 40 - 80% of the capacity of the pump. This will allow the dose rate to be increased should the water quality change, and it is necessary to change the dose rate. Chemical Tank Dosing Pump Calibration Tube Isolation Valves Main …

    Get Price
  • Sizing Chemical Feed Pump - Vitasalus, Inc.

    2014-5-28 · Chemical Feed Pump Sizing Example If pump produces 5 gpm, contains 3 ppm of iron and were using regular 5.25% chlorine bleach Well Pump 5 FLOW RATE X (gpm) Required 3 DOSAGE X (ppm) Time 1440 (min/day) Solution 52500 STRENGTH = (ppm) Required 0.41 FEED RATE (gpd) We offer 2 different size …

    Get Price
  • Pump Calculator Spreadsheet | ITACA

    This spreadsheet allows the user to find the pump power requirement (Watts or Brake Horse Power) for various feeder pipe diameters (in) and given a known flow rate (LPS), pipe length (m) and head (m) and then select a suitable pump based upon available pump characteristic data.

    Get Price
  • CalcVerter: Chemical Metering Pump Feed Rate

    2014-7-20 · 2% solution is required for pumping a 55 gallon feed tank is in use and 12% chemical is available. 55 x 2 ----- = 9.17 gal. chemical to 45.83 gal. water in tank 12 Related Calculators: Chlorine Dosage Calculator; Backwash Water Calculator

    Get Price
  • CheSheets | Chemical Engineering Spreadsheets

    2017-6-26 · CheSheets provide Chemical Engineering Spreadsheets developed in Google Sheets™ - a web based spreadsheet program. To use the sheets copy the spreadsheet to Google Drive™ by clicking Drive Button. After copying open the spreadsheet in Google Sheets™ and do the calculations on go.

    Get Price
  • Chemical Metering Pumps | LMI Pumps

    The metering pump is a positive displacement chemical dosing device with the ability to vary capacity manually or automatically as process conditions require. Approximately 90% of all pumps sold are transfer pumps, which are designed to move liquids from point A to point B.

    Get Price
  • Chemical Injection - Water Treatment Guide

    2019-10-28 · Flocon should be delivered by dosing pump from a dilution tank, direct from the drum or from a bulk storage facility, into the feedwater at a rate that is determined by the size of the membrane system, the recommended dose rate and the delivery range of the dosing pump. It is recommended that the dosing pump …

    Get Price
  • Chemical Dosing Charts - Knorr Systems, Inc.

    2021-5-14 · Providing equipment, service, training and daily operations for the best aquatic facilities in the United States. Daily, our employees are at pools from Seattle to San Diego, from Houston to Tulsa. We haven't seen it all, but we've seen a lot! We bring this depth of experience to each and every pool equipment room. We know …

    Get Price
  • Chemical dosing systems - BIM object definition

    Complete this electronic spreadsheet to ensure that your Chemical dosing systems product information meets the requirements of Level 2 BIM. ... Dosing point 1 process fluid flow rates, Dosing point 2 process fluid flow rates and Dosing point 3 process fluid flow rates. ... Pump of the Chemical dosing systems. Delivery - Supply …

    Get Price
  • (PDF) Chemical dosing calculator for water industry

    Amount of dosing of such chemicals are very important in the purification process. In this paper authors studied importance of chemical dosing for a period of time in a water treatment plant.

    Get Price
  • Dosage Calculator - SPER Chemical

    3.) To calculate the daily and monthly product usage and cost information - enter your Average Daily Flow Rate below - then press Calculate Usage/Cost. Enter average daily water flow in million gallon terms

    Get Price
  • Swimming Pool Chemical Dosing Calculator -

    2021-5-12 · Swimming Pool Chemical Dosing Calculator Use this to calculate the amount of chemicals required to dose your pool in order to correct your levels of Chlorine, pH, Total Alkalinity and Calcium Hardness.

    Get Price
  • Excel Spreadsheets - Cheresources.com

    2017-4-9 · The spreadsheet provides a simple-to-use predictive tool to arrive... 1 reviews 2,504 downloads (19275 views) Added 17 Dec 2015 Featured. FREE Centrifugal Pump Troubleshooting Checklist . By ankur2061 centrifugal, pumps, troubleshoot and 1 more... Troubleshooting checklist for operations and …

    Get Price
  • Chemical Dosing Rate Calculation - Acid Water ...

    2016-9-13 · RE: Chemical Dosing Rate Calculation - Acid Water Neutralisation bimr (Civil/Environmental) 27 Sep 16 14:44 If you know the fluid chemical properties, it is a simple matter to determine the dosing rate.

    Get Price
  • Pulsafeeder Diaphragm Metering Pumps

    2014-1-6 · The flow rate of a metering pump can generally be adjusted in one of two ways. The user can vary the distance that the piston travels, or the speed at which it reciprocates within the pump. For changes in the piston travel, or stroke length, a mechanical adjustment within the pump is used.

    Get Price
  • OURSE MANUA L - nfbwa

    2007-5-15 · A calibration cylinder on each chemical feed pump or a 100, 200, or 500 mL graduated cylinder to measure chemical feed rates 1 A separate rotameter or feed pump for each gas chlorine or ammonia application point. Protective clothing (safety glasses, gloves, etc) when measuring chemical feed rates.

    Get Price
  • Formula Sheet for all Wastewater Operator Exams

    2021-4-29 · 1 Formula Sheet for all Wastewater Operator Exams Revised 8/15 F001 Surface area of a pond, acres = Length, ft x Width, ft …

    Get Price
  • Chemical Dosing Rate Calculation - Industrial ...

    2008-2-12 · Chemical Dosing Rate Calculation - posted in Industrial Professionals: Dear Sirs,I am presently working on a HP chemical dosing system (Tri sodium phosphate) for 80TPH boiler. Please help me in calculating the metering pump flow rate and chemical dosing charge rate for the boiler. Below are the relevant …

    Get Price
  • Chemicals Injection Pumps Calibration Basics -

    2015-2-17 · Calibration of chemical injection pumps is important to ensure that the proper amount of water treatment products are being fed to your systems. All chemical feed pumps are designed to pump at a certain rate; however, the actual flow rate can vary depending upon many conditions. Factors such as discharge …

    Get Price
  • Mining and Mineral Processing Pumps - Flowserve

    2020-1-2 · pump services in the industry. Flowserve has demon-strated application know-how in the industry s toughest services for more than 100 years. Yet, it is also in the forefront of new pumping technologies like those required for deep field bitumen recovery. Whether pumping abrasive slurries or chemical reagents, the …

    Get Price
  • Pulsafeeder Diaphragm Metering Pumps

    2014-1-6 · The flow rate of a metering pump can generally be adjusted in one of two ways. The user can vary the distance that the piston travels, or the speed at which it reciprocates within the pump. For changes in the piston travel, or stroke length, a mechanical adjustment within the pump is used.

    Get Price
  • OURSE MANUA L - nfbwa

    2007-5-15 · A calibration cylinder on each chemical feed pump or a 100, 200, or 500 mL graduated cylinder to measure chemical feed rates 1 A separate rotameter or feed pump for each gas chlorine or ammonia application point. Protective clothing (safety glasses, gloves, etc) when measuring chemical feed rates.

    Get Price
  • White Paper: Water Treatment Process Automation

    2007-8-2 · adjust chemical feed rates, determine pump ef-ficiency and power requirements, and calculate detention times. Venturi flow meters, in combina-tion with accurate differential pressure transmitters, are most commonly used in water treatment plants due to their ability to handle large volumes of water and their low …

    Get Price
  • Progressive Cavity - Netzsch Nemo | Excel Fluid

    2021-5-8 · Progressive Cavity. Excel Fluid Group offers NETZSCH NEMO Progressive Cavity Pumps. NEMO® Progressing Cavity Pumps have a very broad application range and are used in all branches of industry for the continuous, pressure-stable, gentle and low-pulsation conveyance of almost any substance. One advantage for …

    Get Price
  • Effective Chemical Management Program -

    2021-5-14 · Current oilfield production chemical management practices for land-based fracked wells, providing a window into emerging trends. This discussion is very timely due to the extraordinary challenges that the industry is facing: long-term low oil prices, skilled-labor shortage, and the COVID-19 pandemic. To offset the …

    Get Price
  • Cooling Tower Basic Calculations - Yamatho

    2017-2-28 · The recirculation rate and the temperature drop across the cooling tower are the two pieces of data needed to calculate the amount of water lost from the open recirculating cooling system (due to evaporation). Following items will be discussed and calculated in this article : - Evaporation - Temperature Drop - Recircul

    Get Price
  • How to Optimize Polymer Efficiency for Better Sludge ...

    2019-6-1 · Inversion of Emulsion: water-in-oil oil-in-water 99.5% Water 70% Polymer gel 30% Oil Oil Polymer gel Polymer 1 gal Water 100 gal Neat Polymer > 1.0 % Polymer Solution Inverting Surfactant Especially Important for Clarifier at WTP - Strip “oil” off the polymer surface - Help polymer get exposed to water quickly

    Get Price
  • Chemicals Injection Pumps Calibration Basics -

    2015-2-17 · Calibration of chemical injection pumps is important to ensure that the proper amount of water treatment products are being fed to your systems. All chemical feed pumps are designed to pump at a certain rate; however, the actual flow rate can vary depending upon many conditions. Factors such as discharge …

    Get Price
  • Wastewater chemical dosing systems - BIM

    Complete this electronic spreadsheet to ensure that your Wastewater chemical dosing systems product information meets the requirements of Level 2 BIM. ... Dosing point 1 process fluid flow rates, Dosing point 2 process fluid flow rates and Dosing point 3 process fluid flow rates. ... Pump of the Wastewater chemical dosing systems…

    Get Price
  • USE OF AN SRT CALCULATOR TO ASSIST WITH

    2017-8-1 · dosing. SRT cannot be measured directly as it is a function of the influent loads, chemical dosing, sludge wasting rates, and solids capture efficiencies. A spreadsheet-based SRT calculator was developed for the Colac Water Reclamation Plant (WRP) to account for all these factors.

    Get Price
  • Indigo Water Group Home Page

    2017-11-20 · cfs, what is the concentration of raw chemical in the dosing tank? Ferric chloride is being added as a coagulant to the influent to a secondary clarifier. Sampling shows that the concentration of ferric in the clarifier floc well is 25 ppm. A quick check of the chemical metering pump shows that it is operating at a flow …

    Get Price
  • Mining and Mineral Processing Pumps - Flowserve

    2020-1-2 · pump services in the industry. Flowserve has demon-strated application know-how in the industry s toughest services for more than 100 years. Yet, it is also in the forefront of new pumping technologies like those required for deep field bitumen recovery. Whether pumping abrasive slurries or chemical reagents, the …

    Get Price
  • Adjusting the pH of Water with a Chemical Feed

    Chemical Feed Pump or Neutralizing Filter The Use of Soda Ash and Caustic Soda to Alter pH Neutralizing Filters and Chemical-Feed Pumps. Neutralizing filters and chemical-feed pumps adjust the pH of water. A pH of 7 is neutral, while a pH less than 7 is acidic, and a pH greater than 7 is alkaline. Water should be as close to pH …

    Get Price
  • SAMPLE CALCULATIONS: Chlorine Feed Rate

    2012-4-4 · SAMPLE CALCULATIONS: Chlorine Feed Rate Chlorine is added to water to kill any disease-causing organisms which may be present in the water or may enter the water as it travels through the distribution system.

    Get Price
  • Preventive maintenance program: Guide for small

    2017-7-31 · pressure tank problems. If a pump cycles on-off more than 6 times an hour, it may indicate a bladder failure in a bladder tank or a “water-logged” condition in a hydropneumatic tank. High frequency pump cycling wears out the pump motor, switches, and controls. Many water systems use a pump alternator or lead/lag pump …

    Get Price
  • Metering Pumps - ProMinent

    2021-5-14 · Pump Guide. The choice of pumps is huge: 80 industries, 100,000 products and infinite applications. To make it as easy as possible to find your ideal metering pump, ProMinent designed the Pump Guide. All it takes is a few clicks to find a selection of suitable models. How it works. First enter the pump capacity …

    Get Price
  • Quick Determination of the Methanol Injection

    2009-4-1 · To demonstrate the application of the proposed charts, example 6.6 in Volume 1 of “Gas Conditioning and Processing,” [11] is considered. In this example it is stated that 3.5 × 10 6 Sm 3 /d of natural gas leaves an offshore platform at 40 o C and 8000 kPa. The hydrate temperature of the gas is 17 o C. The gas arrives …

    Get Price
  • Formulas for Calculating Medication Dosage

    2015-9-30 · Our pump rate is always mL/hour, so we need to multiply our mcg/min by 60 to get mcg/h. 210 x 60 = 12,600, so we will be giving 12,600 mcg/h. ADN 841: Nursing Seminar II Learning Unit 3: Handout Page 5 of 6 Now we have to find out how many mL contain our 12,600 mcg. We will use our concentration number

    Get Price
  • Dilution & Dosage Calculator - PWT

    Antiscalant Dosage Calculator should be used to calculate the amount of PWT antiscalant delivered by dosing pump from a dilution tank, direct from the drum or from a bulk storage facility, into the feed water based on the feed flow and the desired PWT antiscalant active dosage concentration.

    Get Price
  • Chemicals Injection Pumps Calibration Basics -

    2015-2-17 · Calibration of chemical injection pumps is important to ensure that the proper amount of water treatment products are being fed to your systems. All chemical feed pumps are designed to pump at a certain rate; however, the actual flow rate can vary depending upon many conditions. Factors such as discharge …

    Get Price
  • PUMP MAINTENANCE SCHEDULE AND CHECKLISTS

    2019-10-29 · PUMP MAINTENANCE SCHEDULE AND CHECKLISTS Providing a maintenance schedule defined specifically by run hours or yardage pumped serves only as a general guideline given the large amount of variables a unit might be subject to, such as weather and ambient temperature conditions, jobsite conditions, …

    Get Price
  • Indigo Water Group Home Page

    2017-11-20 · cfs, what is the concentration of raw chemical in the dosing tank? Ferric chloride is being added as a coagulant to the influent to a secondary clarifier. Sampling shows that the concentration of ferric in the clarifier floc well is 25 ppm. A quick check of the chemical metering pump shows that it is operating at a flow …

    Get Price
  • Useful Irrigation Formulas & Charts - The Urban

    Application Rates of Emitter-Line Grids – This simple formula allows the precise calculation of application rates in inches per hour. Just enter the emitter rate (GPH), the spac-ing of the emitter-line that you are using in inches, and the spacing of the laterals in inches into the formula. Application Rates of Point source Drip Systems …

    Get Price
  • Basic Water Treatment Math Formulas for Surface and

    2018-6-19 · Revised 9/15 Basic Water Treatment Math Formulas for Surface and Well Exams These formulas are intended to serve as a general resource and are not intended to be an all‐inclusive list. AREA

    Get Price
  • Adjusting the pH of Water with a Chemical Feed

    Chemical Feed Pump or Neutralizing Filter The Use of Soda Ash and Caustic Soda to Alter pH Neutralizing Filters and Chemical-Feed Pumps. Neutralizing filters and chemical-feed pumps adjust the pH of water. A pH of 7 is neutral, while a pH less than 7 is acidic, and a pH greater than 7 is alkaline. Water should be as close to pH …

    Get Price
  • Wastewater Pump Draw Down Calculator | Pumps

    2011-12-17 · Pump curve for a duplex lift station. Figure 1 shows the pump curve for a duplex lift station that was designed to pump 400 gallons per minute (gpm) into a gravity main against a static head of 48 feet. The red, horizontal line is the system head at the pump-start level in the wet well. In this example, any friction in the …

    Get Price
  • Pool Calculator - Swimming Pool Maintenance

    Pool Calculator provides the tools and maintenance information you need to keep your swimming pool and hot tub chemicals balanced and …

    Get Price
  • Wastewater Pump Station Design Spreadsheet

    2016-10-19 · This spreadsheet is to be used as a tool for design engineers to design pump station and force main systems to connect to the Brunswick County Collection System. The use of this spreadsheet does not relieve the design engineer of the responsibility of verifying the results of the spreadsheet and taking into account …

    Get Price
  • SUMMARY OF KEY WASTEWATER MATH FORMULAS

    2014-9-12 · 1. Chemical Feed Pumps: GPD = ( Required Feed, Lbs/Day ) = (MGD) x mg/L x 8.34 ( Dry lbs/Gal ) ( Dry lbs/Gal ) 2. Chemical Feed Rate: GPD = ( Feed, ml/minute x 1,440 min/day ) ( 1,000 ml/L x 3.785 L/gallon ) ml/min = ( GPD x 1,000 ml/L x 3.785 L/Gallon ) ( 1,440 min/day ) ml/min = ( GPM x 3,785 ml/gal ) 3.

    Get Price
  • Reports, Templates & Fact Sheets | nyruralwater.org

    Reports, Templates & Fact Sheets. To download, simply right click on the file of your choice and choose 'save target as' and choose a location on your hard drive or network to save the file. The files are in either MS Word 97-2000 or MS Excel 97-2000 formats. Please note that all formulas in the operators reports and …

    Get Price
  • Water Treatment Online Tools & Calculators | SUEZ

    2021-5-13 · Pump Tools is designed to help you find the Tonkaflo pump that best fits your need. The Pump Search helps users, who are familiar with the Tonkaflo product line, to get information on a particular model. You can type in model numbers, part numbers, family designations (AS, QS or SS) or series information (12500, 5500, …

    Get Price
  • Basic Water Treatment Math Formulas for Surface and

    2018-6-19 · Revised 9/15 Basic Water Treatment Math Formulas for Surface and Well Exams These formulas are intended to serve as a general resource and are not intended to be an all‐inclusive list. AREA

    Get Price
  • Phosphorus Removal Analysis - WWOA

    phosphorus loading patterns, the varying chemical dosing levels can be configured via with the plant’s SCADA system using these trends. Third party laboratory analysis –data used for reporting purposes. This data can also be used to fine-tune chemical dosage, but the long wait times are a problem for “real time” control.

    Get Price
  • WELL SERVICE TECHNOLOGIES | Intervention

    Liquid treatments including biocides and oxygen scavenger are injected via a chemical injection pump or by pre-mixing. Chemical injection dosing can be regulated and automated depending on the specific requirements of the customer. The metering skid comprises of multiple flowmeters and pressure transducers records volumes, rates …

    Get Price
  • Sediment Basin Design Fact Sheet - austieca.com.au

    the settling pond, and if chemical dosing is required, selecting the most appropriate flocculant and/or coagulant, and then achieving effective ‘mixing’ prior to the treated flows entering the settling pond. 3. The size of the settling pond is directly related to the ‘volume’ of runoff and/or peak design ‘discharge’.

    Get Price
  • Activated Sludge Waste Water Treatment

    2010-11-19 · Activated Sludge Background. The activated sludge process is the most widely used method of biological wastewater treatment around the world. This process, only about 100 years old, was invented in England in 1914, and rapidly came into widespread use.An activated sludge wastewater treatment plant with an …

    Get Price
  • SLUDGE DEWATERING - SNF Holding Company

    2016-8-19 · 1.2.5. Physico-chemical sludge: This type of sludge is the result of a physico-chemical treatment of the wastewater(see brochure “Coagulation Flocculation”). It is composed of flocs produced by the chemical treat-ment (coagulants and/or flocculants). The characteristics of this sludge is the direct …

    Get Price